  • Two years later he complained of

    2019-06-24

    Two years later, he complained of two ICD shocks during a dance party. The possibility of lead fracture or electromagnetic interference was completely excluded after several examinations. Intracardiac electrograms showed that all delivered shocks were inappropriate therapies due to TWOS. The R wave amplitude was 8.0mV, which was slightly decreased compared to that at implantation, but we could not observe TWOS. Although we performed various challenging tests (exercise, body position, and drinking) (Fig. 1A, B), TWOS was not reproduced. Considering the situation of the ICD shocks (singing and dancing while drinking), we performed a body twisting test. TWOS was reproduced by Fmoc-Val-OH of body twisting (semi-sitting position with twisting to the right) (Fig. 1C) after exercise or isoproterenol (ISP) infusion. The TWOS disappeared when the sensitivity was changed from 0.3mV to 0.9mV (Fig. 1D). The ventricular sensitivity threshold was set at 0.9mV, and defibrillation testing was performed to ensure no undersensing. The defibrillation test demonstrated good VF detection. The patient has not suffered from inappropriate ICD therapies due to TWOS for a Fmoc-Val-OH of of 4 years despite participating in some dance parties.
    Case 2 A 30-year-old man was referred to our hospital with the complaint of repeated syncope. After several examinations, he was diagnosed as having Brugada syndrome. A single chamber ICD (Lumax 340 VR-T, Biotronik Inc., Berlin, Germany) was implanted. A dedicated bipolar dual-coil ICD lead (Linox TD 65/18, Biotronik Inc.) was used. The pacing threshold was 0.2V at 0.5ms; R wave amplitude, 7.0mV; and lead impedance, 755Ω at implantation. Ventricular tachyarrhythmia detections were programmed only in the VF zone above 200bpm. Therapy consisted of one antitachycardia pacing followed by ICD shocks. Sensitivity of the R wave was set at 0.8mV. A remote monitoring system (CardioMessenger, Biotronik Inc.), which was used with a land line, was set up in his bedroom immediately after discharge. Three months after discharge, we received an emergency e-mail for VF detection. An intracardiac electrogram obtained from a web site showed that the ICD misdiagnosed sinus tachycardia as VF due to TWOS, and antitachycardia pacing was delivered but not ICD shocks. The patient was asked to visit our outpatient clinic the next day. The possibility of lead fracture or electromagnetic interference was completely excluded after several examinations. He was taking a bath while performing stretching exercises during the inappropriate ICD therapies. The R wave amplitude was 5.0mV, which was slightly decreased compared to that at implantation, but we could not observe TWOS. Although we performed various challenging tests (exercise and body position) (Fig. 2A, B), TWOS was not reproduced. Considering the situation of the ICD shocks (stretching in a hot bath), we performed a body twisting test. TWOS was reproduced by body twisting (standing position with twisting to the left) after exercise or ISP infusion (Fig. 2C). The TWOS disappeared when the sensing filter was switched from standard mode to enhanced T wave suppression mode (Fig. 2D). After switching the filter setting, the patient has not suffered from inappropriate ICD therapies due to TWOS during a period of 2 years despite taking a bath while performing stretching exercises every day. Appropriate ICD shocks were successfully delivered after 2 years.
    Discussion TWOS has been the main cause of ventricular oversensing followed by inappropriate ICD therapies. Some algorithms to differentiate the T wave from the R wave have been developed, and the proportion of TWOS has been decreased [4]. The clinical impact of case 1 may be limited because of the old generator. If TWOS appeared, the management could be difficult. TWOS is likely to be observed during sinus tachycardia but not at rest. Several methods to avoid TWOS, such as changing the sensitivity, adding a new lead, exchanging the kind of generator, and changing the filter setting, have been reported. However, we experienced a prior case in which TWOS could not be reproduced despite of several examinations such as an exercise test, electrophysiological test, and body position test. At that time, we did not think of performing a body twisting test after an exercise test or ISP infusion. We changed the sensitivity threshold without clear evidence. However, TWOS reappeared. As in our prior case, only sensitivity changing without any evidence often fails to prevent TWOS [1–3]. Therefore, it is important, but sometimes difficult, to reproduce TWOS in order to manage TWOS by a noninvasive method. In our two cases, we could reproduce TWOS by body twisting after an exercise test or ISP infusion. We accidentally found TWOS in the first case during movement to the supine position after an exercise test.